Research-Grade Polarimeter
Equipment Model
Rudolph Research Analytical Autopol III (AP111-6W-10)
Description
The Rudolph Research Analytical Autopol III (AP111-6W-10) is a research-grade polarimeter designed for high-precision analysis of optically active substances. It measures optical rotation, specific rotation, and concentration of chiral compounds and supports multi-wavelength and temperature-controlled measurements. This instrument is used extensively in pharmaceutical, chemical, and academic laboratories for both routine and advanced analysis.
Lab
CIF Room No: 3154
Institute
Central Analytical Laboratory
Location
CIF Room No: 3154, Birla Institute of Technology & Science, Vidya Vihar, Pilani, Rajasthan 333031, India
Applications
Pharmaceutical Industry: Determination of enantiomeric excess and concentration of chiral drugs under GMP/GLP compliance.
Chemical Synthesis: Stereochemical analysis and process verification of optically active intermediates.
Food Industry: Quantification of sugar solutions (e.g., sucrose, glucose) and quality control of sweeteners.
Biochemistry: Study of biomolecules such as amino acids, carbohydrates, and glycoproteins.
Academic & Industrial Research: Investigations involving conformational changes, mutarotation, and kinetic optical rotation studies.
Regulatory Compliance: Suitable for cGMP environments with 21 CFR Part 11 software integration.
Key Features
High-accuracy measurement of optical and specific rotation over a wide concentration and path length range.
Multi-wavelength support (up to 6 wavelengths) for wavelength-dependent optical rotation studies.
Integrated Peltier-based temperature control for precise thermal regulation.
21 CFR Part 11 compliant software for secure data logging and audit trails.
Touchscreen interface with programmable methods and real-time data display.
Limitations
Higher cost due to advanced features and regulatory compliance support.
Requires regular calibration and maintenance for maximum precision.
Sample preparation (e.g., filtration, degassing) is critical for accurate readings.
Limited to optical activity measurements—cannot provide structural data like NMR or MS.
Bulkier than basic polarimeters, requiring dedicated benchtop space.
Pricing
₹400
This instrument has 1 available procedures. Please select a procedure to book the instrument.
Select ProcedureProcedures
All procedures available for this instrument are listed below.
Availability
View the current availability for this instrument. Red slots indicate booked times.
April 2026
Available
Booked
Unavailable